RL78/G1A APPENDIX A REVISION HISTORY
(3/5)
Page Description Classification
CHAPTER 11 A/D CONVERTER
p.361 Modification of Figure 11-1. Block Diagram of A/D Converter (c)
p.365 Modification of caution 1 in Figure 11-2. Format of Peripheral Enable Register 0 (PER0) (c)
p.367 Modification of Table 11-1. Settings of ADCS and ADCE Bits (c)
p.378 Modification of caution 1 in Figure 11-6. Format of A/D Converter Mode Register 1 (ADM1) (c)
p.379, 380 Modification of caution in Figure 11-7. Format of A/D Converter Mode Register 2 (ADM2) (c)
p.385
Modification of caution 5 in Figure 11-11. Format of Analog Input Channel Specification Register
(ADS)
(c)
CHAPTER 12 SERIAL ARRAY UNIT
p.424 Modification of note 1 in 12.1.1 3-wire serial I/O (CSI00, CSI01, CSI10, CSI11, CSI20, CSI21) (c)
p.449
Modification of 12.3.14 Serial standby control register 0 (SSC0), and addition of Table 12-2.
Interrupt Using the UART Reception with SNOOZE Mode
(c)
p.451 Modification of description in 12.3.16 Noise filter enable register 0 (NFEN0) (c)
p.520
Modification of figure and addition of note 2 to Figure 12-72. Timing Chart of SNOOZE Mode
Operation (once startup) (Type 1: DAPmn = 0, CKPmn = 0)
(c)
p.522
Modification of figure and addition of note 2 to Figure 12-74. Timing Chart of SNOOZE Mode
Operation (continuous startup) (Type 1: DAPmn = 0, CKPmn = 0)
(c)
p.547
Modification of description and caution 2 and addition of cautions 3, 4 to 12.6.3 SNOOZE mode
function
(c)
p.548 Addition of Table 12-3. UART Reception Baud Rate Setting in the SNOOZE mode (c)
p.549 Addition of description in 12.6.3 (1) SNOOZE mode operation (EOCm1 = 0, SSECm = 0/1) (c)
p.550
Addition of description in 12.6.3 (2) SNOOZE mode operation (EOCm1 = 1, SSECm = 0: error
interrupt (INTSRE0) generation enable)
(c)
p.551
Modification of Figure 12-93. Flowchart of SNOOZE Mode Operation (EOCm1 = 0, SSECm = 0/1
or EOCm1 = 1, SSECm = 0)
(c)
p.552
Modification of 12.6.3 (3) SNOOZE mode operation (EOCm1 = 1, SSECm = 1: error interrupt
(INTSRE0) generation stop)
(c)
p.553, 554 Modification of Figure 12-95. Flowchart of SNOOZE Mode Operation (EOCm1 = 1, SSECm = 1) (c)
p.557 Modification of 12.6.4 (2) Baud rate error during transmission (c)
CHAPTER 14 MULTIPLIER AND DIVIDER/MULTIPLY-ACCUMULATOR
p.685 Modification of description in 14.4.1 Multiplication (unsigned) operation (c)
p.686 Modification of description in 14.4.2 Multiplication (signed) operation (c)
p.687 Modification of description in 14.4.3 Multiply-accumulation (unsigned) operation (c)
p.689 Modification of description in 14.4.4 Multiply-accumulation (signed) operation (c)
p.690
Modification of Figure 14-9. Timing Diagram of Multiply-Accumulation (signed) Operation
(2 × 3 + (4) = 2 32767 × (1) + (2147483647) = 2147450882 (overflow occurs.))
(c)
p.691 Modification of description in 14.4.5 Division operation (c)
CHAPTER 16 INTERRUPT FUNCTION
p.715 Addition of Note 5 to Table 16-1. Interrupt Source List (a)
Remark “Classification” in the above table classifies revisions as follows.
(a): Error correction, (b): Addition/change of specifications, (c): Addition/change of description or note,
(d): Addition/change of package, part number, or management division, (e): Addition/change of related
documents
R01UH0305EJ0200 Rev.2.00 971