RL78/G1A CHAPTER 6 TIMER ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 268
Jul 04, 2013
Figure 6-64. Operation Procedure When Delay Counter Function Is Used
Software Operation Hardware Status
Power-off status
(Clock supply is stopped and writing to each register is
disabled.)
Sets the TAUmEN bit of peripheral enable register 0
(PER0) to 1.
Power-on status. Each channel stops operating.
(Clock supply is started and writing to each register is
enabled.)
TAU
default
setting
Sets timer clock select register m (TPSm).
Determines clock frequencies of CKm0 to CKm3.
Channel
default
setting
Sets corresponding bit of noise filter enable register 1
(NFEN1) to 0 (OFF) or 1 (ON).
Sets timer mode register mn (TMRmn) (determines
operation mode of channel).
INTTMmn output delay is set to timer data register mn
(TDRmn).
Clears the TOEmn bit to 0 and stops operation of TOmn.
Channel stops operating.
(Clock is supplied and some power is consumed.)
Sets the TSmn bit to 1.
The TSmn bit automatically returns to 0 because it is a
trigger bit.
TEmn = 1, and the start trigger detection (the valid edge
of the TImn pin input is detected or the TSmn bit is set to
1) wait status is set.
Operation
start
The counter starts counting down by the next start trigger
detection.
• Detects the TImn pin input valid edge.
• Sets the TSmn bit to 1 by the software.
Value of the TDRmn register is loaded to the timer count
register mn (TCRmn).
During
operation
Set value of the TDRmn register can be changed.
The TCRmn register can always be read.
The TSRmn register is not used.
The counter (TCRmn) counts down. When the count
value of TCRmn reaches 0000H, the INTTMmn output is
generated, and the count operation stops until the next
start trigger detection (the valid edge of the TImn pin input
is detected or the TSmn bit is set to 1).
Operation
stop
The TTmn bit is set to 1.
The TTmn bit automatically returns to 0 because it is a
trigger bit.
TEmn = 0, and count operation stops.
The TCRmn register holds count value and stops.
TAU
stop
The TAUmEN bit of the PER0 register is cleared to 0.
Power-off status
All circuits are initialized and SFR of each channel is
also initialized.
Remark m: Unit number (m = 0), n: Channel number (n = 0 to 7 (however, timer input pin (TImn), timer output pin
(TOmn) : n = 0, 1, 3 to 7))
Operation is resumed.