RL78/G1A CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 480
Jul 04, 2013
(2) Operation procedure
Figure 12-57. Initial Setting Procedure for Slave Reception
Starting initial settings
Setting the PER0 register
Setting the SPSm register
Setting the SMRmn register
Setting the SCRmn register
Setting the SDRmn register
Setting port
Writing to the SSm register
Completing initial setting
Release the serial array unit from the
reset status and start clock supply.
Set the operation clock.
Set an operation mode, etc.
Set a communication format.
Set baud rate setting (bits 15 to 9) to
0000000B.
Enable data input and clock input of the
target channel by setting a port register
and a port mode register.
Set the SSmn bit of the target channel to 1
(SEmn bit = 1: to enable operation). Wait for
a clock from the master.
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), mn = 00 to 03, 10, 11