RL78/G1A CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 423
Jul 04, 2013
12.3.10 Serial channel enable status register m (SEm)
The SEm register indicates whether data transmission/reception operation of each channel is enabled or stopped.
When 1 is written a bit of serial channel start register m (SSm), the corresponding bit of this register is set to 1. When 1
is written a bit of serial channel stop register m (STm), the corresponding bit is cleared to 0.
Channel n that is enabled to operate cannot rewrite by software the value of the CKOmn bit (serial clock output of
channel n) of serial output register m (SOm) to be described below, and a value reflected by a communication operation is
output from the serial clock pin.
Channel n that stops operation can set the value of the CKOmn bit of the SOm register by software and output its value
from the serial clock pin. In this way, any waveform, such as that of a start condition/stop condition, can be created by
software.
The SEm register can be read by a 16-bit memory manipulation instruction.
The lower 8 bits of the SEm register can be set with a 1-bit or 8-bit memory manipulation instruction with SEmL.
Reset signal generation clears the SEm register to 0000H.
Figure 12-13. Format of Serial Channel Enable Status Register m (SEm)
Address: F0120H, F0121H (SE0) After reset: 0000H R
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
SE0 0 0 0 0 0 0 0 0 0 0 0 0 SE03 SE02 SE01 SE00
Address: F0160H, F0161H (SE1)
Note
After reset: 0000H R
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
SE1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SE11 SE10
SEmn Indication of operation enable/stop status of channel n
0 Operation stops
1 Operation is enabled.
Note 32, 48, 64-pin products only
Caution Be sure to clear bits 15 to 4 of the SE0 register and bits 15 to 2 of the SE1 register to “0”.