RL78/G1A CHAPTER 16 INTERRUPT FUNCTIONS
Figure 16-4. Format of Priority Specification Flag Registers (PR00L, PR00H, PR01L, PR01H, PR02L, PR02H,
PR10L, PR10H, PR11L, PR11H, PR12L, PR12H) (2/2)
<R>
Address: FFFEBH After reset: FFH R/W
Symbol <7> 6 5 4 <3> <2> <1> <0>
PR01H TMPR004 1 1 1 KRPR0 ITPR0 RTCPR0 ADPR0
Address: FFFEFH After reset: FFH R/W
Symbol <7> 6 5 4 <3> <2> <1> <0>
PR11H TMPR104 1 1 1 KRPR1 ITPR1 RTCPR1 ADPR1
Address: FFFD8H After reset: FFH R/W
Symbol <7> <6> <5> <4> <3> <2> <1> <0>
PR02L PPR010 PPR09 PPR08 PPR07 PPR06 TMPR007 TMPR006 TMPR005
Address: FFFDCH After reset: FFH R/W
Symbol <7> <6> <5> <4> <3> <2> <1> <0>
PR12L PPR110 PPR19 PPR18 PPR17 PPR16 TMPR107 TMPR106 TMPR105
Address: FFFD9H After reset: FFH R/W
Symbol <7> 6 <5> 4 3 2 1 <0>
PR02H FLPR0 1 MDPR0 1 1 1 1 PPR011
Address: FFFDDH After reset: FFH R/W
Symbol <7> 6 <5> 4 3 2 1 <0>
PR12H FLPR1 1 MDPR1 1 1 1 1 PPR111
XXPR1X XXPR0X Priority level selection
0 0 Specify level 0 (high priority level)
0 1 Specify level 1
1 0 Specify level 2
1 1 Specify level 3 (low priority level)
Caution The available registers and bits differ depending on the product. For details about the registers and
bits available for each product, see Table 16-2 Be sure to set bits that are not available to the initial
value.
<R>
R01UH0305EJ0200 Rev.2.00 702
Jul 04, 2013