RL78/G1A CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 450
Jul 04, 2013
(2) Operation procedure
Figure 12-33. Initial Setting Procedure for Master Reception
Set an operation mode, etc.
Starting initial setting
Setting the PER0 register
Setting the SPSm register
Setting the SMRmn register
Setting the SCRmn register
Setting the SDRmn register
Setting the SOm register
Setting port
Writing to the SSm register
End of initial setting
Release the serial array unit from the
reset status and start clock supply.
Set the operation clock.
Set a communication format.
Set the initial output level of the serial
clock (CKOmn).
Enable clock output of the target channel
by setting a port register and a port mode
register.
Set dummy data to the SIOp register (bits
7 to 0 of the SDRmn register) and start
communication.
Set the SSmn bit of the target channel to 1
(SEmn bit = 1: to enable operation).
Set a transfer baud rate (setting the
transfer clock by dividing the operation
clock (f
MCK
)).
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21),
mn = 00 to 03, 10, 11