RL78/G1A CHAPTER 6 TIMER ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 234
Jul 04, 2013
(b) When operation starts with slave channel output mode (TOMmp = 1) setting (PWM output))
When slave channel output mode (TOMmp = 1), the active level is determined by timer output level register m
(TOLm) setting.
Figure 6-33. TOmp Pin Output Status at PWM Output (TOMmp = 1)
Hi-Z
Active
TOEmp
Default
status
Set
Reset
Set
Reset
Set
Port output is enabled
TOmp
(output)
ActiveActive
TOmp bit = 0
(Default status : Low)
TOmp bit = 1
(Default status : High)
TOmp bit = 0
(Default status : Low)
TOmp bit = 1
(Default status : High)
TOmp bit = 0
(Active high)
TOmp bit = 1
(Active low)
Remarks 1. Set: The output signal of the TOmp pin changes from inactive level to active level.
Reset: The output signal of the TOmp pin changes from active level to inactive level.
2. m: Unit number (m = 0), p: Channel number (p = 1, 3 to 7)