RL78/G1A CHAPTER 6 TIMER ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 205
Jul 04, 2013
Figure 6-11. Format of Timer Mode Register mn (TMRmn) (4/4)
Address: F0190H, F0191H (TMR00) to F019EH, F019FH (TMR07) After reset: 0000H R/W
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TMRmn
(n = 2, 4, 6 )
CKS
mn1
CKS
mn0
0
CCS
mn
MAST
ERmn
STS
mn2
STS
mn1
STS
mn0
CIS
mn1
CIS
mn0
0 0
MD
mn3
MD
mn2
MD
mn1
MD
mn0
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TMRmn
(n = 1, 3)
CKS
mn1
CKS
mn0
0
CCS
mn
SPLIT
mn
STS
mn2
STS
mn1
STS
mn0
CIS
mn1
CIS
mn0
0 0
MD
mn3
MD
mn2
MD
mn1
MD
mn0
Symbol 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TMRmn
(n = 0, 5, 7)
CKS
mn1
CKS
mn0
0
CCS
mn
0
Note
STS
mn2
STS
mn1
STS
mn0
CIS
mn1
CIS
mn0
0 0
MD
mn3
MD
mn2
MD
mn1
MD
mn0
Operation mode
(Value set by the MDmn3 to MDmn1 bits
(see table shown in the previous page))
MD
mn0
Setting of starting counting and interrupt
0
Timer interrupt is not generated when counting is started
(timer output does not change, either).
Interval timer mode
(0, 0, 0)
Capture mode
(0, 1, 0)
1
Timer interrupt is generated when counting is started
(timer output also changes).
Event counter mode
(0, 1, 1)
0
Timer interrupt is not generated when counting is started
(timer output does not change, either).
0
Start trigger is invalid during counting operation.
At that time, interrupt is not generated.
One-count mode
Note 1
(1, 0, 0)
1
Start trigger is valid during counting operation
Note 2
.
At that time, interrupt is not generated.
Capture & one-count mode
(1, 1, 0)
0
Timer interrupt is not generated when counting is started
(timer output does not change, either).
Start trigger is invalid during counting operation.
At that time interrupt is not generated.
Other than above Setting prohibited
Notes 1. Bit 11 is fixed at 0 of read only, write is ignored.
2. In one-count mode, interrupt output (INTTMmn) when starting a count operation and TOmn output are
not controlled.
3. If the start trigger (TSmn = 1) is issued during operation, the counter is initialized, and recounting is
started (does not occur the interrupt request).
Remark m: Unit number (m = 0), n: Channel number (n = 0 to 7 (however, timer input pin (TImn), timer output pin
(TOmn) : n = 0, 1, 3 to 7))