RL78/G1A CHAPTER 11 A/D CONVERTER
R01UH0305EJ0200 Rev.2.00 379
Jul 04, 2013
11.6.8 Hardware trigger no-wait mode (scan mode, one-shot conversion mode)
<1> In the stop status, the ADCE bit of A/D converter mode register 0 (ADM0) is set to 1, and the system enters the
A/D conversion standby status.
<2> After the software counts up to the stabilization wait time
Note
, the ADCS bit of the ADM0 register is set to 1 to
place the system in the hardware trigger standby status (and conversion does not start at this stage). Note that,
while in this status, A/D conversion does not start even if ADCS is set to 1.
<3> If a hardware trigger is input while ADCS = 1, A/D conversion is performed on the four analog input channels
specified by scan 0 to scan 3, which are specified by the analog input channel specification register (ADS). A/D
conversion is performed on the analog input channels in order, starting with that specified by scan 0.
<4> A/D conversion is sequentially performed on the four analog input channels, the conversion results are stored in
the A/D conversion result register (ADCR, ADCRH) each time conversion ends, and the A/D conversion end
interrupt request signal (INTAD) is generated.
<5> After A/D conversion of the four channels ends, the ADCS bit remains set to 1, and the system enters the A/D
conversion standby status.
<6> If a hardware trigger is input during conversion operation, the current A/D conversion is interrupted, and
conversion restarts at the first channel. The partially converted data is discarded.
<7> When the value of the ADS register is rewritten or overwritten during conversion operation, the current A/D
conversion is interrupted, and A/D conversion is performed on the first channel respecified by the ADS register.
The partially converted data is discarded.
<8> When ADCS is overwritten with 1 during conversion operation, the current A/D conversion is interrupted, and
conversion restarts at the first channel. The partially converted data is discarded.
<9> When ADCS is cleared to 0 during conversion operation, the current A/D conversion is interrupted, and the
system enters the A/D conversion standby status. However, the A/D converter does not stop in this status.
<10> When ADCE is cleared to 0 while in the A/D conversion standby status, the A/D converter enters the stop status.
When ADCS = 0, inputting a hardware trigger is ignored and A/D conversion does not start.
Note If a high-accuracy channel is selected as the analog input channel: Stabilization wait time = 0.5
μ
s
If a standard channel is selected as the analog input channel: Stabilization wait time = 2
μ
s
Figure 11-24. Example of Hardware Trigger No-Wait Mode (Scan Mode, One-Shot Conversion Mode)
Operation Timing
Trigger
standby
status
Conversion
standby
Stop
status
Stop
status
ADCE is set to 1.
<1>
ADCE
ADCS
ADS
INTAD
ADCR,
ADCRH
A/D
conversion
status
Hardware
trigger
ADCS is set to 1.
<2>
A hardware trigger
is generated.
<3> <3>
<3>
<3>
The trigger is not
acknowledged.
The interrupt is generated four times. The interrupt is generated four times. The interrupt is generated four times.
Conversion
standby
Conversion
standby
Conversion
standby
Conversion
standby
ADCS retains
the value 1.
<5>
<5> <5>
<4>
A/D
conversion
ends.
Conversion is
interrupted
and restarts.
Conversion is
interrupted
and restarts.
Conversion is
interrupted
and restarts.
Conversion is
interrupted.
Data 1
(ANI0)
Data 1
(ANI0)
Data 2
(ANI1)
Data 5
(ANI0)
Data 6
(ANI1)
Data 11
(ANI0)
Data 11
(ANI0)
Data 12
(ANI1)
Data 18
(ANI5)
Data 21
(ANI6)
Data 2
(ANI1)
Data 3
(ANI2)
Data 3
(ANI2)
Data 4
(ANI3)
Data 7
(ANI0)
Data 8
(ANI1)
Data 8
(ANI1)
Data 9
(ANI2)
Data 9
(ANI2)
Data 10
(ANI3)
Data 10
(ANI3)
Data 13
(ANI4)
Data 13
(ANI4)
Data 17
(ANI4)
Data 19
(ANI4)
Data 20
(ANI5)
Data 20
(ANI5)
Data 14
(ANI5)
Data 14
(ANI5)
Data 15
(ANI6)
Data 15
(ANI6)
Data 16
(ANI7)
Data 16
(ANI7)
Data 4
(ANI3)
<4>
<4>
<8>
A hardware trigger is
generated during A/D
conversion operation.
<6>
ADS is rewritten
during A/D
conversion operation.
<7>
ADCS is overwritten
with 1 during A/D
conversion operation.
ADCS is cleared
to 0 during A/D
conversion
operation.
ADCE is cleared to 0.
<10>
Data 5
(ANI0)
Data 17
(ANI4)
ANI0 to ANI3
ANI4 to ANI7
<9>
The trigger is not
acknowledged.
Data 19