12.8.5 Calculating transfer rate
The transfer rate for simplified I
2
C (IIC00, IIC01, IIC10, IIC11, IIC20, IIC21) communication can be calculated by the
following expressions.
(Transfer rate) = {Operation clock (f
MCK) frequency of target channel} ÷ (SDRmn[15:9] + 1) ÷ 2
Caution SDRmn[15:9] must not be set to 00000000B. Be sure to set a value of 00000001B or greater
for SDRmn[15:9]. The duty ratio of the SCL signal output by the simplified I
2
C is 50%. The I
2
C
bus specifications define that the low-level width of the SCL signal is longer than the high-
level width. If 400 kbps (fast mode) or 1 Mbps (fast mode plus) is specified, therefore, the low-
level width of the SCL output signal becomes shorter than the value specified in the I
2
C bus
specifications. Make sure that the SDRmn[15:9] value satisfies the I
2
C bus specifications.
Remarks 1. The value of SDRmn[15:9] is the value of bits 15 to 9 of the SDRmn register (0000001B to
1111111B) and therefore is 1 to 127.
2. m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), mn = 00 to 03, 10, 11
The operation clock (f
MCK) is determined by serial clock select register m (SPSm) and bit 15 (CKSmn) of serial mode
register mn (SMRmn).