RL78/G1A CHAPTER 6 TIMER ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 233
Jul 04, 2013
(2) Default level of TOmn pin and output level after timer operation start
The change in the output level of the TOmn pin when timer output register m (TOm) is written while timer output is
disabled (TOEmn = 0), the initial level is changed, and then timer output is enabled (TOEmn = 1) before port
output is enabled, is shown below.
(a) When operation starts with master channel output mode (TOMmn = 0) setting
The setting of timer output level register m (TOLm) is invalid when master channel output mode (TOMmn = 0).
When the timer operation starts after setting the default level, the toggle signal is generated and the output
level of the TOmn pin is reversed.
Figure 6-32. TOmn Pin Output Status at Toggle Output (TOMmn = 0)
Hi
-
Z
TOE
mn
TOm
n
(output)
TOmn bit = 0
(Default status : Low)
Default
status
Port output is enabled
Toggle ToggleToggleToggleToggle
Bold : Active level
TOmn bit = 1
(Default status : High)
TOmn bit = 0
(Default status : Low)
TOmn bit = 1
(Default status : High)
TOmn bit = 0
(Active high)
TOmn bit = 1
(Active low)
Remarks 1. Toggle: Reverse TOmn pin output status
2. m: Unit number (m = 0), n: Channel number (n = 0, 1, 3 to 7)