RL78/G1A CHAPTER 29 ELECTRICAL SPECIFICATIONS (T
A = 40 to +85°C)
R01UH0305EJ0200 Rev.2.00 862
Jul 04, 2013
Notes 1. Total current flowing into VDD and EVDD0, including the input leakage current flowing when the level of the input
pin is fixed to VDD, EVDD0 or VSS, EVSS0. The values below the MAX. column include the peripheral operation
current. However, not including the current flowing into the A/D converter, LVD circuit, I/O port, on-chip pull-
up/pull-down resistors, and data flash rewriting.
2. During HALT instruction execution by flash memory.
3. When high-speed on-chip oscillator and subsystem clock are stopped.
4. When high-speed system clock and subsystem clock are stopped.
5. When high-speed on-chip oscillator and high-speed system clock are stopped. When RTCLPC = 1 and setting
ultra-low current consumption (AMPHS1 = 1). Including the current flowing into the RTC. However, not
including the current flowing into the 12-bit interval timer, and watchdog timer.
6. When subsystem clock is stopped. Not including the current flowing into the RTC, 12-bit interval timer,
watchdog timer.
7. Relationship between operation voltage width, operation frequency of CPU and operation mode is as below.
HS (high-speed main) mode: 2.7 V V
DD 3.6 V@1 MHz to 32 MHz
2.4 V V
DD 3.6 V@1 MHz to 16 MHz
LS (low-speed main) mode: 1.8 V V
DD < 3.6 V@1 MHz to 8 MHz
LV (low-voltage main) mode: 1.6 V VDD 3.6 V@1 MHz to 4 MHz
8. Regarding the value for current to operate the subsystem clock in STOP mode, refer to that in HALT mode.
Remarks 1. f
MX: High-speed system clock frequency (X1 clock oscillation frequency or external main system clock
frequency)
2. f
IH: High-speed on-chip oscillator clock frequency
3. fSUB: Subsystem clock frequency (XT1 clock oscillation frequency)
4. Except subsystem clock operation and STOP mode, temperature condition of the TYP. value is T
A = 25°C