NEC 2400IMX Answering Machine User Manual


 
NDA-24282 CHAPTER 4
Page 59
Revision 1.0
PA-AL16 (ALMC)
PA-AL16 (ALMC)
1. Function
This circuit card collects fault information and manages a dual-configuration system of the ACD Module
Type System. The card displays the collected fault information on the TOPU. Besides, the card provides
the functions for data communication between two ACDPs in the dual system configuration.
2. Mounting Location/Condition
The mounting location of this circuit card and the condition related to mounting are shown below.
When ACDP is provided by single system configuration in the IMG (IMX), this circuit card is to be
mounted in its mounting slot only when the APMA is installed externally.
CPU
APINT APINT
CPU CPU
COPY COPY
CRAM CRAM
IOC
ACD-MIS
ALMC
RS-232C (Non-protocol)
IMX ACD system (Module Type)
I/O LOCAL BUS
(ACDP) (ACDP)
APM-A\E
Position within the System
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mounting Module APM-A\E
PA-AL16