CHAPTER 6 NDA-24282 (E)
Page 324
Revision 1.0
ACD SERVICE FEATURES FUNCTIONAL TEST PROCEDURES
NAP-215-110
Sheet 1/1
After Call Work (Automatic)
Log off all ACD agent and supervisory
positions, then log on only one position.
Office data change.
• Using the ACDSPL command, assign 0 (Automatic After Call Work mode setting) to parameter
AFTER.
C.O. trunk incoming.
• Place a C.O. trunk call from station A to station C.
Incoming at ACD agent position.
Answering by ACD agent position.
C.O. trunk incoming.
• Place a C.O. trunk call from station B to station C.
Release by ACD agent position, automatic setting of After Call Work mode.
• Check that, when the agent position release, the After Call Work mode is set automatically.
Release of After Call Work mode.
• Press the WORK key so that the WORK lamp goes out.
Incoming at ACD agent position.
Answering by ACD agent position.
• The agent position starts communication with station B.
Release by ACD agent position.
Release of office data.
Apply the test procedure above to all splits.
START
END
COT
LC
A
B
C
D
ELC/DLC
Agent Position