NEC 2400IMX Answering Machine User Manual


 
CHAPTER 4 NDA-24282 (E)
Page 140
Revision 1.0
PA-4DATA (4DAT)
Note:
When this circuit card is being used as an external hold tone source, set 0, 4 or 6 by timer mode.
SW9
Note
E
Set to E while the circuit card is in use as an-
nouncement equipment only.
0
Designation of Circuit No. 0.
The timer is 16-sec. mode.
1
Designation of Circuit No. 1.
The timer is 16-sec. mode.
2
Designation of Circuit No. 2.
The timer is 16-sec. mode.
3
Designation of Circuit No. 3.
The timer is 16-sec. mode.
4
Designation of Circuits No. 0 and No. 1.
The timer is 32-sec. mode.
5
Designation of Circuits No. 2 and No. 3.
The timer is 32-sec. mode.
6
Designation of All Circuits.
The timer is 60-sec. mode.
F Recording from a telephone set.
SW10
0
ON
Circuit No. 0 make busy request.
Circuit No. 0 is designated during a recording.
OFF × Circuit No. 0 make busy request cancel.
1
ON
Circuit No. 1 make busy request.
Circuit No. 1 is designated during a recording.
OFF × Circuit No. 1 make busy request cancel.
2
ON
Circuit No. 2 make busy request.
Circuit No. 2 is designated during a recording.
OFF × Circuit No. 2 make busy request cancel.
3
ON
Circuit No. 3 make busy request.
Circuit No. 3 is designated during a recording.
OFF × Circuit No. 3 make busy request cancel.
SW12
(WR KEY)
UP
Recording from a tape recorder. (WRITE
mode)
DOWN × Normal setting
SWITCH
NAME
SWITCH NO. SETTING
STANDARD
SETTING
MEANING