NDA-24282 (E) CHAPTER 4
Page 171
Revision 1.0
PA-GT16 (MBB)
3. Locations of Lamps, Switches, and Connectors
The locations of lamps, switches, and connectors equipped on this circuit card are shown below.
4. Lamp Indications
The meaning of indication of each lamp on this circuit card is shown below.
LAMP COLOR MEANING OF INDICATION
OPE Green Remains lit while this circuit card and ETHER card are normally operating
LAN ALM Red
Lights when the processor in ETHER card has become faulty or when ETHER
card is not correctly connected with this circuit card
SW0
BUS
OPE
SEG
MB
LAN ALM
MBRQ