NEC 2400IMX Answering Machine User Manual


 
CHAPTER 7 NDA-24282
Page 336
Revision 1.0
ASYD: ASSIGNMENT OF SYSTEM DATA
Note 4:
Terminal Control Facility Indirect is used for displays, LED functions, and chimes for ACD positions. The
standard choice has both bit 1 and bit 2 set to “1”.
Note 5:
Terminal Control Facility Direct is used for certain ACDP entries and displays from ACD positions.
Note 6:
ASYD, System Data 1, index 59, bit 2 must also be set to a 1 for this feature to operate.
Note 1:
Must be set to “1” for an “IF NOT QUEUED GO TO BUSY 11 step to return busy tone to a self-directing
trunk (CCV function on DIDs etc.). This does not work with ringdown type trunks.
Note 2:
When the announcement service is used in Fusion network, this data is set to nodes that accommodates the
announcement trunk.
Note 3:
Be sure to assign the data value “1” here (see Chapter 1, Section 1.3, “Precaution on Using the ACD Fea-
tures”).
Note 4:
When changing the value of this data bit to “0” (OAI/ACD Service Provided) from “1” (OAI/ACD Service
Not Provided), system initialization must be executed.
System Data-1 Programming Sheet
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 ~ 255
DATA
(DATA)
00 ~ FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
59 b
2
DID busy condition
0/1 = No/Yes
Note 1
70 1 b
6
ACD Announcement service 0/1=Out of service/In
service.
Note 2
79
b
4
Warning tone sent to the monitored position.
0/1=No/Yes
Note 3
0b
6
OAI/ACD Service
Note 4
0 = ACD In Service; 1 = ACD Out of Service
80 0 b
3
Line of the LCD for static ACD messages (Break, Ready,
etc.) display.
0/1=top line/second line