ACD SERVICE FEATURES FUNCTIONAL TEST PROCEDURES
NAP-215-114
Sheet 1/2
Night Service
Use one of the following three methods to change
into the night mode.
(1) Automatic changeover into the night mode
based on the ACD call control vector (Night
Announcement setting using ACD CCV command).
(2) Pressing the NIGHT key on the supervisory position of split C; as this display confirmation message
Night Mode?, enter 1# to change over into the night mode.
(3) Changeover into the night mode by means of operation at the MIS terminal of the supervisory posi-
tion.
Night Announcement
Place a C.O. trunk call from station A to station B in the special night split.
Station A hears the night announcement.
Apply the test procedure above to all splits.
Using the ACD CCV command, change the night services of the split and test each of the following ser-
vices repeatedly.
Night Service Change
Using the ACD CCV command, change the night services of the split and test each of the following ser-
vices.
Night Transfer to Station
Place a C.O. trunk call from station A to station B.
Call incoming at transfer destination station.
A
START
ELC/DLC
LC
A
B
COT
ATI
ELC/DLC
Announcement Trunk
Split C
D: ATT