NEC 2400IMX Answering Machine User Manual


 
NDA-24282 (E) CHAPTER 4
Page 127
Revision 1.0
PA-16ELCJ (16ELC)
5. Switch Settings
Standard settings of various switches on this circuit card are shown in the table below.
Note 1: APR-J/APA-J is an optional device to be connected to D
term
and provides interface for analog terminal.
Note 2: By setting SW01-1 and SW01-7 as explained in the table below, either APR-J/APA-J or Data Adapter can be used.
SWITCH
NAME
SWITCH
NO.
SETTING
STANDARD
SETTING
MEANING
SW01
1
Note 1
Note 2
ON When APR-J/APA-J is not connected.
OFF
When APR-J/APA-J is connected.
2
ON × Fixed ON
OFF
3
ON × Fixed in the system.
OFF
4
ON × Fixed in the system.
OFF Dual Port Mode.
5
ON × Fixed in the system.
OFF
6
ON × Fixed in the system.
OFF
7
ON 16ELC Mode
OFF 8DLC Mode
8
ON × Fixed in the system.
OFF
SW00
(MB)
UP Circuit card make busy.
DOWN × Circuit card make busy cancel.
SW01-7
ON OFF
SW01-1
ON
Up to 16 circuits can be connected.
Only voice is used.
Up to 8 circuits can be connected.
Simultaneous communications of voice and
data (use of Data Adapter) can be done.
Make this setting when using Data Adapter.
OFF
Up to 16 circuits can be connected.
Simultaneous communications of voice and
data (use of APR-J/APA-J) cannot be done.
When either data or voice is used by changing
over with APR-J/APA-J.
Up to 8 circuits can be connected.
Simultaneous communications of voice and
data (use of APR-J/APA-J) can be done.