Toshiba CTX28 Telephone User Manual


 
Strata CTX
Configuration
Strata CTX Configuration
Primary/Reserve Power Cabinet Hardware
Strata CTX I&M 06/04 2-53
Cabinet AC Power Component Installation
After the cabinets have been floor mounted, the AC power components should be installed Tables
2-69 and 2-70 show the primary AC power components required for floor mounted systems.
Table 2-69 Floor Mount Cabinet Component Requirements for 120VAC Primary Power
Local
Electrical
Code
1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets 7 Cabinets
3 or more
cabinets
require a
conduit box
1 – BFIF 1 – BFIF
1 -BCCB120
1
1 – BFIF
1 – BCCB120
1
1 – RPSB2
1 – BFIF
1. A BCCB120 conduit connection box must be installed and wired by a certified electrician per the local electrical code.
1 – BCCB120
1
2 – RPSB2
1 – BFIF
1 – BCCB120
1
2 – RPSB2
1 – BFIF
N/A
Table 2-70 Floor Mount Cabinet Component Requirements for 208VAC or 240VAC Primary Power
Local
Electrical
Code
1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets 7 Cabinets
3 or more
cabinets
require a
conduit box
1 – BACL240
1 – BFIF
1 – BCCB240
1
2 – BACL240
1 – BFIF
1. A BCCB240 conduit connection box must be installed and wired by a certified electrician per the local electrical code.
1 – BCCB240
1
1 – BPSB240
3 – BACL240
1 – BFIF
1 – BCCB240
1
1 – BPSB240
4 – BACL240
1 – BFIF
1 – BCCB240
1
2 – BPSB240
5 – BACL240
1 – BFIF
1 – BCCB240
1
2 – BPSB240
6 – BACL240
1 – BFIF
1 – BCCB240
1
3 – BPSB240
7 – BACL240
1 – BFIF