Strata CTX I&M 06/04 4-33
Strata CTX670
Installation
Cabinet Floor Mounting
The part numbers and descriptions of the floor mounting hardware are shown in Table 4-6.
Floor Mounting One or Two Cabinets
1. Remove front, side, and top covers from cabinet(s) (Figure 4-5). Remove plastic locating parts
from all cabinet back covers using a Phillips screwdriver.
2. Make sure that cabinet power supplies (BPSU672A) are installed per “Install Power Supply”
on page 4-6.
3. If installing just one or two cabinets, install the BFIF fixtures on each side of the bottom of the
cabinet (Figure 4-19) and place the cabinet where it should be installed.
4. Set the bottom cabinet on the floor or mount surface, then set the top cabinet on the bottom
cabinet.
5. Fasten the two cabinets together with the four screws provided: (two screws at front “A” and
two at back “B” of cabinet. Place cabinet where it should be installed.
6. Connect the Expansion Cabinet data cable to the “CAB. 2” data cable connector on the Base
Cabinet (Figures 4-9 and 4-12).
...or if installing a Remote Expansion Cabinet: see details in “Remote Cabinet Installation
Instructions” on page 4-56.
7. Install ground wiring, AC and reserve power cabling, and PCB cabling per the “Recommended
Installation Sequence” on page 4-6.
8. Fill out cabinet/slot identification labels on cabinet(s) (Figure 4-8).
9. Reinstall covers on to cabinets (Figure 4-5).
Table 4-6 Floor Mount Hardware
Option Description
BCCB120 or
BCCB240
CTX670 conduit connection box that is installed in the base cabinet, side panel. It is used to
hardwire Primary AC power and reserve battery power connections through conduit. These
boxes are required by UL for three or more floor mounted cabinets. Conduit boxes are not
required for wall mounted systems with any number of cabinets or floor mounted system with
one or two cabinets. They can be used as an option on any system.
The BCCB120 is required when connecting AC120VAC as the primary power source and the
BCCB240 is required when connecting AC208VAC or AC240VAC as the primary power
source.
BCCB conduit boxes must be field installed by a certified electrician.
BFIF
Floor mount fixture kit is required when floor mounting two or more CTX670 cabinets.
Provides two metal stands for mounting any number of CTX670 cabinets on floor. Three
pairs or wall brackets (RWBF) are supplied with BFIF to use when mounting three or more
CTX670 cabinets on floor. The wall brackets are needed to secure floor-mounted systems to
the wall for safety purposes.