Toshiba CTX28 Telephone User Manual


 
Strata CTX Configuration
CTX100 Max. Capacity Configuration Examples
2-28 Strata CTX I&M 06/04
CTX100 Max. Capacity Configuration Examples
The tables in this section summarize the maximum capacities of digital telephones with various
types of line circuits. A PCB placement diagram for each numbered configuration follows tables.
Digital Telephones and Loop Start Lines With or Without Caller ID
Table 2-11 CTX100 Base Cabinet with Analog, Loop Start Lines
4 Universal Slots
40 Stations (Max.)
24 CO lines (Max.)
44 Stations + Analog loop start lines combined (Max.)
Table No. Stations Analog loop start lines
2-12 40 4 (none can have Caller ID)
2-13 32 8 (all can have Caller ID)
2-14 32 16 (none can have Caller ID)
2-15 16 16 (8 can have Caller ID)
2-16 24
1
1. Using ADKU.
8 (none can have Caller ID)
Table 2-12 CTX100 Base: 40 stations, 4 loop start lines, 0 CLID
S101 S102
S103
1
1. S103 is only 8 DKTs and S104 is only 4 lines because of cabinet
power factor
S104
BDKU/
BDKS
BDKU/
BDKS
ADKU RCOU
16 DKTs 16 DKTs 8 DKTs 4 lines