Toshiba CTX28 Telephone User Manual


 
IP Telephony and QSIG Over IP
CTX IP Troubleshooting
Strata CTX I&M 06/04 9-39
IP Telephony and QSIG
Over IP
IPT Problems:
15
“IPT shows ““Can’t
register IPT:E4””.”
Find the IPT which has same
Station ID.
Station ID duplicated. Set unique Station ID.
16
“IPT shows ““Can’t
register IPT:E11””.”
No resources are available.
Create a new IPT terminal in
Prog 200. Or, Change
destination BIPU having
some idle resources.”
17
“IPT shows ““Can’t
register IPT:E13””.”
“Check CTX applies Terminal
Authentication feature, or, IP
address filtering. Verify Prog 150
FK2 and Prog 250 FK5, FK6 for
Terminal Authentication. Verify
Prog 250 FK2, FK3 for IP
address filtering.”
1. Terminal Authentication
feature was applied but
Station MAC address was
different from that
programmed in CTX.
2. IP address filtering was
applied but Station IP
address was different from
that programmed in CTX.”
See Spec.1203 for Terminal
Authentication. See
Spec.1200 for IP address
filtering.”
18
“IPT shows ““BIPU TCP
CONNECT ERROR””.”
Fail to establish TCP
connection to BIPU.
19
“IPT shows ““BIPU TCP
PORT IS CLOSED””.”
TCP connection was
disconnected by BIPU.
20
“IPT shows ““BIPU ALIVE
PACKET STOP””.”
Keep-Alive was failing.
21
22
Table 9-10 IP Troubleshooting Problems and Resolutions
(continued)
No. Problem Action Cause How to Resolve