Toshiba CTX28 Telephone User Manual


 
Strata CTX
Configuration
Strata CTX Configuration
Worksheet 8 – CTX Primary AC and Reserve Power
Strata CTX I&M 06/04 2-47
Worksheet 8 – CTX Primary AC and Reserve
Power
CTX100 AC Power Considerations
The power supply in each Strata CTX100 Base and Expansion Cabinet furnishes power to all of
the stations and some of the interface peripherals (see Table 2-59). The primary AC power for each
cabinet is 120VAC.
CTX670 AC Power Considerations
The power supply in each Strata CTX670 Base and Expansion Cabinet furnishes power to all of
the stations and some of the interface peripherals (see Table 2-60). The primary AC power can be
120VAC, 208VAC or 240VAC. Systems containing six or seven cabinets require 208VAC or
240VAC.
Table 2-59 Strata CTX100 Electrical Characteristics
Strata CTX100 Primary AC Power Voltage
Input AC
AC Frequency
Watts per cabinet (maximum)
120VAC
60 Hz, Single-phase (48Hz~62Hz)
100 watts (maximum)
Strata CTX100 Primary Power Current Consumption (Rating in Amperes)
120VAC
1 cabinet
2 cabinets
1.8 amps
3.6 amps
Power Supply Unit (APSU112A)
DC voltage output specification
-24VDC (-26.3~-27.8VDC, 3.2 DC amps)
+5VDC (+4.5~5.5VDC, 2.0 DC amps)
-5VDC (-4.5~-5.5VDC, 0.2 DC amps)
+3.3VDC (+3.0~3.6VDC, 0.5 DC amps
Table 2-60 Strata CTX670 Electrical Characteristics
Strata CTX670 Primary AC Power Voltage
Input AC
AC Frequency
Watts per cabinet (continuous)
Watts for five cabinet system
115
±10VAC or 208±20VAC or 240±20VAC
50/60 Hz, Single-phase (48~62Hz)
180
900
Strata CTX670 Primary Power Current Consumption (Rating in Amperes)
120VAC 208VAC 240VAC
1 cabinet
2 cabinets
3 cabinets
4 cabinets
5 cabinets
6 cabinets
7 cabinets
3.2 amps
6.4 amps
9.6 amps
12.8 amps
16.0 amps
N/A
N/A
2.2 amps
4.4 amps
6.6 amps
8.8 amps
11.0 amps
13.2 amps
15.4 amps
2.0 amps
4.0 amps
6.0 amps
8.0 amps
10.0 amps
12.0 amps
14.0 amps
Power Supply Unit (BPSU672)
DC voltage output specification
-24VDC (-26.3~-27.8VDC, 6.0 DC amps)
+5VDC (+4.5~5.5VDC, 4.0 DC amps)
-5VDC (-4.5~-5.5VDC, 0.8 DC amps)