Ground the System
Strata CTX I&M 06/04 4-19
Strata CTX670
Installation
Figure 4-11 Cabinet Grounding
Cabinet Motherboard
Cabinet
Motherboard
Cabinet
Motherboard
Cabinet
Motherboard
Cabinet
Motherboard
FG Screws
Base
Cabinet
Power
Supply
FG (Frame Ground) Screws
The Single Point Ground must always be connected to
the Base Cabinet Power Supply FG Screw
(Top cabinet - Wall Mount or Bottom cabinet - Floor Mount.)
Expansion
Cabinets
Up to six
Inter-cabinet green wires
supplied with each cabinet
Green/Green Yellow
ground wires from
Motherboard
Earth Ground:
AWG #6 Wire
(minimum)
Length: 60 Feet
(maximum)
Per General Rules of Article
250 of the National Electric
Code, NFPA70
ONEAC 6-AP
or 6-DP
Solid State
Secondary
Protectors
Third Wire
AC Ground
Insulated Ground Wire “B”
Note:
The impedance of the link
between point “A” and “B” must
be less than 0.25 ohms.
Note:
The ground must be
routed through the
same conduit as the
phase conductors
serving the system.
Single Point Ground (SPG)
Cold Water Pipe or Ground Rod
Note:
The SPG cannot be structural
steel members or conduit.
“A”
“A”
Note:
The impedance of
the link between
point “A” and “B”
must be less than
0.25 ohms.
Note:
The impedance of
the link between
point “A” and “B”
must be less than
0.25 ohms.
120VAC System Primary Power ( 1-5 cabinets only )
Building Main Power
Panel Electrical Ground
208VAC ± 20VAC (50/60 Hz)
or 240VAC ± 20VAC (50/60 Hz)
Dedicated 20 Amp
Branch Circuit.
If 208VAC is used, the plug may have to be
changed by a licensed electrician.
Note:
The system may be
powered by 120, 208,
or 240VAC.
NEMA 6-20R,
240VAC
208 or 240VAC System Primary Power ( 1-7 cabinets )
115VAC ± 10VAC (50/60 Hz)
Dedicated 20 Amp
Branch Circuit
Building Main Power
Panel Electrical Ground
“B”
AWG #6 Wire
(minimum)
Length: 60 Feet
(maximum)
Point “B” is always on the
Base Cabinet, whether it's
on the top or bottom.
NEMA 5-15R,
120VAC
5044
The cabinets must be
located no more than 9
feet from the AC outlet.