This section defines the installation site requirements necessary to ensure a proper operating
environment for the CTX28. Also included are grounding requirements.
Input Power
The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 1.5 amps. The AC
outlet is recommended to be dedicated and unswitched. (See “AC Power and Grounding
Requirements” on page 1-4.)
This eliminates interference from branch circuit motor noise or the like, and to prevent accidental
power-off. To avoid accidental power turn-off, Toshiba recommends that you do not use an On/Off
wall switch on this dedicated AC circuit.
For the Strata CTX28, a reserve power source (HPFB-6) may be connected to the system to serve
as a power failure backup (See Step 8 on page 1-18).
Clearance and Location
The minimum clearance requirements for the
Strata CTX28 Base cabinet is shown in
Figure 1-1. Refer to Figure 1-5 on page 1-7 for
CTX28 KSU mounting instructions.
Consider the following conditions when selecting
a location for the KSU(s):
The location must be:
Dry and clean
Well ventilated
Well illuminated
Easily accessible
The location must not be:
Subject to extreme heat or cold
Subject to corrosive fumes, dust, or other
airborne contaminants
Subject to excessive vibration
Next to television, radio, office automation, or
high frequency equipment
If reserve power (HPFB-6) is to be installed for
the Strata CTX28, the batteries will require a
well-ventilated location close to the CHSU28A.
2" 2"
2"
2"
18"
Front View
12.25"
Top View
3.5"
3 Feet
Wall
CTX28
Base KSU
7062
Figure 1-1 CTX28 Base KSU Clearance
Requirements