PCB Installation
BIOU – Option Interface Units
Strata CTX I&M 06/04 6-9
PCB Installation
BIOU – Option Interface Units
Circuits per PCB:
(see interfaces)
Interfaces with:
three music-on-hold sources, system page and control relays
Older Version(s):
none
The BIOU provides a Paging Output (amplified and non-amplified), four zone paging relays, three
Music-on-hold (MOH) interfaces and four control relays (Night Transfer, Night Bell and
Background Music (BGM) mute). One or two BIOUS can be installed in a Strata CTX.
BIOU controls, indicators, and interface connectors are shown in Figure 6-5 and described in
Table 6-4.
BIOU Installation
³ Insert the BIOU (component side facing right) into any available PCB slot in the cabinet. See
“Worksheet 6: Strata CTX670 Cabinet Slots” on page 2-37. Apply firm, even pressure to
ensure proper mating of connectors.