Toshiba CTX28 Telephone User Manual


 
CTX28 Installation
MDF Wiring
1-24 Strata CTX I&M 06/04
MDF Wiring
For Registration information refer to “CTX28 FCC/ACTA Registration Numbers” on page 1-1.
Figure 1-19 MDF Wiring to CO Lines (GMAU and GCDU)
Table 1-14 Station Wiring for Amphenol Connector (P1) on GMAU1
Pin No. Signal Pin No. Signal Station
1 VR1 26 VT1 DKT #1
2 VR2 27 VT2 DKT #2
3 VR3 28 VT3 DKT #3
4 VR4 29 VT4 DKT #4
5 VR5 30 VT5 DKT #5
6 VR6 31 VT6 DKT #6
7 VR7 32 VT7 DKT #7
8 VR8 33 VT8 DKT #8
9 VR9 34 VT9 DKT #9
10 VR10 35 VT10 DKT #10
11 VR11 36 VT11 DKT #11
12 VR12 37 VT12 DKT #12
13 VR13 38 VT13 DKT #13
14 VR14 39 VT14 DKT #14
15 VR15 40 VT15 DKT #15
16 VR16 41 VT16 DKT #16
17 (NC) 42 (NC)
18 PF1R 43 PF1T PFT circuit*
19 (NC) 44 (NC)
20 (NC) 45 (NC)
21 (NC) 46 (NC)
22 (NC) 47 (NC)
23 CR1 48 CT1 STU #1
24 (NC) 49 (NC)
25 CR2 50 CT2 STU #2
* Connect a Standard Telephone to PFT pair to provide access to CO Line1 during a power failure.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
48
49
50
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
48
49
50
BRIDGING
CLIPS
66M150 SPLIT BLOCK
GN
654321
Y
BL
R
BK
W
2345
MODULAR
CORD
1-6
T1
R1
T1
R1
TO
NETWORK
R1
T1
GMAU
GCDU
CO1~6
MODULAR
JACKS
R2
R1
T1
T2
5
4
3
2
GMAU
GCDU
PIN-OUT
1
2
3456
NETWORK JACK: RJ14C
FIC: 02LS2
CO LINE CABLING
7262