Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
1 - 34
1 Installation
MITSUBISHI CNC
<Display of spindle PLG diagnosis>
Installation diagnosis for spindle side PLG encoder
Details of each diagnosis signal bit which is displayed as information for spindle PLG diagnosis are shown in the
following table.
Item Details
Encoder Diagn L Display the motor end PLG diagnosis signal bit 7 to 0.
Encoder Diagn H Display the motor end PLG diagnosis signal bit F to 8.
Sub Encoder Diagn L Display the machine end PLG diagnosis signal bit 7 to 0.
Sub Encoder Diagn H Display the machine end PLG diagnosis signal bit F to 8.
Information for spindle PLG diagnosis
(For details of each diagnosis signal bit,
refer to the next page.)
When an error is detected with spindle PLG diagnosis
"1" is displayed on the corresponding
diagnosis signal bit
To CN3
To CN2
Spindle
motor
Spindle
MU1606 (Gear)
TS5690 (Sensor)
Spindle
gear
Motor gear
MU1606 (Gear)
TS5690 (Sensor)
Open loop
1)
Power ON
1)
Power ON
5
)
Judgment with the diagnosis signal bit
by the PLG diagnosis display
3)
NC power ON again
2)
Open loop control parameter setting
4)
Spindle rotation with 100r/min command