Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 140
4 Setup
MITSUBISHI CNC
#13065 SP065 TLM1 Torque limit 1
Set the torque limit value when "the torque limit (control input 1/bitA, 9, 8) " is set to "001".
---Setting range---
0 to 999 (Short-time rated %)
#13066 SP066 TLM2 Torque limit 2
Set the torque limit value when "the torque limit (control input 1/bitA, 9, 8)" is set to "010".
---Setting range---
0 to 999 (Short-time rated %)
#13067 SP067 TLM3 Torque limit 3
Set the torque limit value when "the torque limit (control input 1/bitA, 9, 8) " is set to "011".
---Setting range---
0 to 999 (Short-time rated %)
#13068 SP068 TLM4 Torque limit 4
Set the torque limit value when "the torque limit (control input 1/bitA, 9, 8) " is set to "100".
---Setting range---
0 to 999 (Short-time rated %)
#13069 SP069 PCMP Phase alignment completion width
Set the single-rotation position alignment completion width for phase alignment and changing from
non-interpolation to spindle synchronization mode during rotation.
Set the rotation error that is required to the machine.
When the setting value decreases, the rotation error will decrease, but the cycle time (settling time)
will get longer. The standard setting is "875".
---Setting range---
0 to 32767 (1°/1000)
#13070 SP070 KDDT Phase alignment deceleration rate scale
Set the scale for SP016 (DDT) to change the deceleration rate only during rotation command
(command F Δ T 0).
When the setting value increases, the single-rotation position alignment will be completed faster, but
the impact to the machine will also increase. When not using, set to "0".
---Setting range---
0 to 255 (1/16-fold)
#13071 SP071 DIQM Variable current limit during deceleration, lower limit value
Set this parameter to adjust the deceleration time by changing the current limit value during
deceleration depending on the motor speed.
As shown below, set the lower limit rate of the current limit in SP071 (DIQM), and use with SP072
(DIQN).
When DIQM is set to 100%, the standard current limit value in deceleration (TMLR) is applied.
---Setting range---
0 to 999 (%)
DIQN
0
DIQM
100%
(TMLR)
Motor speed