Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
5 - 56
5 Servo Adjustment
MITSUBISHI CNC
[5] Spindle drive unit in the 2nd part system controls power supply unit.
Vertical axis is a 1-axis unit in the 1st part system (vertical axis: Z axis).
(Note) For the standard setting value of SV056, refer to "Deceleration control".
Axis
Parameter
Axis other than the right Z axis (Vertical axis) Spindle
MDS-D2/DH2-V2 MDS-D2/DH2-V1 MDS-D2/DH2-SP
SV048 0
200ms as a standard
(Set by adjustment)
Set as follows.
SP055=20000
SP056=300
SV055 Each axis Maximum value of SV056 setting value +100ms
SV056 Standard setting value for each axis (Note)
CAUTION
In the 2nd part system of the power supply, if the axis for vertical axis drop prevention is connected with the CN9 connector
of the power supply unit, provide the vertical axis drop prevention control setting also for the drive unit connected with CN4
connector of the same power supply unit.
MDS-D2/DH2-V1
MDS-D2/DH2-V2 MDS-D2/DH2-SP MDS-D2/DH2-CV
࡮࡮࡮
࡮࡮࡮
NC
NC
MDS-D2/DH2-V2
MDS-D2/DH2-V2
Spindle
Power supply
(1st part system)
(2nd part system)
*Z axis