Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 143
MDS-D2/DH2 Series Instruction Manual
4.3 Setting the Initial Parameters for the Spindle Drive Unit
#13079 SP079 IQG Q axis current gain
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
#13080 SP080 IDG D axis current gain
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
#13081 SP081 IQAL Q axis current lead compensation low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 20480
#13082 SP082 IDAL D axis current lead compensation low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 20480
#13083 SP083 IQGL Q axis current gain low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
#13084 SP084 IDGL D axis current gain low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
#13085 SP085
Not used. Set to "0".
#13086 SP086
Not used. Set to "0".