Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
3 - 9
MDS-D2/DH2 Series Instruction Manual
3.2 Emergency Stop Observation
(2) Parameter setting for servo drive unit
Starts the SLS (Safely Limited Speed) function.
#2313 SV113 SSF8 Servo function 8
bit F : ssc SLS (Safely Limited Speed) function
0: Stop  1: Start
The digital signal input selection is set to "1" for the drive unit connected with the door state signal. The digital signal
input selection is set to "0" for the other drive unit not connected with the signal.
#2282 SV082 SSF5 Servo function 5
bit F-C: dis Digital signal input selection
0: No signal
1: SLS (Safely Limited Speed) function door state signal
2: Battery box voltage drop warning
3 to F: Setting prohibited
CAUTION
1. The SLS (Safely Limited Speed) function is NC option. Make sure the compatibility with this function.
2. Make sure to input one of the door status signal for each control system to CN9 connector of servo or spindle drive unit.
In the control system, it is conveyed to the axis which is not directly connected via the NC.
3. Using the SLS (Safely Limited Speed) function, it is required to set parameter in addition to the wiring mentioned above.
To prevent a certain axis from being involved in the SLS (Safely Limited Speed) function, set SV113/bitF or SP229/bitF
to 0.