Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
1 Installation
MITSUBISHI CNC
1 - 2
1.1 Installation of Servo Motor
1.1.1 Environmental Conditions
CAUTION
1. Do not hold the cables, axis or encoder when transporting the motor. Failure to observe this could lead to faults or
injuries.
2. Securely fix the motor to the machine. Insufficient fixing could lead to the motor deviating during operation. Failure to
observe this could lead to injuries.
3. When coupling to a servo motor shaft end, do not apply an impact by hammering, etc. The encoder could be damaged.
4. Never touch the rotary sections of the motor during operations. Install a cover, etc., on the shaft.
5. Do not apply a load exceeding the tolerable load onto the servo motor shaft. The shaft could break. Failure to observe
this could lead to injuries.
6. Do not connect or disconnect any of the connectors while the power is ON.
Environment Conditions
Ambient temperature 0°C to +40°C (with no freezing)
Ambient humidity 80% RH or less (with no dew condensation)
Storage temperature -15°C to +70°C (with no freezing)
Storage humidity 90% RH or less (with no dew condensation)
Atmosphere
Indoors (no direct sunlight)
No corrosive gas, inflammable gas, oil mist or dust
Altitude
Operation / storage: 1000m or less above sea level
Transportation: 10000m or less above sea level