2.5 Motor and Encoder Connection
2.5.5 Connection of Tool Spindle Motor
(1) Connecting the HF-KP46 / HF-KP56 / HF-KP96
(2) Connecting the HF-SP226 / HF75 / HF105 / HF54 / HF104 / HF154 / HF224
U
V
W
1
2
3
4
1
RQ
2
RQ*
3
CNT
4
BT
5
LG(GND)
6
SD
7
SD*
8
9
SHD
P5 (+5V)
1 2 3 4
JN4AT04NJ1-R
U V W
CN2L
MDS-D2-SP
CMV1-R10P
8
4
5
7
6
9
10
1
2
3
+5V)
5
LG
RQ*
SD*
2
4
6
8
10
P5(
RQ
SD
BT
1
3
7
9
Power connector
Power wire and grounding wire
(Refer to Specification manual for details
on selecting the wire.)
Ground
Optional cable: CNV2E
(Refer to Appendix 2 for details on the
cable treatment.)
Max : 10m
Encoder connector
NamePin
NamePin
Name
Pin
Name
Pin
Pin No.
Encoder connector : CN2L
No.9 No.1
No.10 No.2
1
RQ
2
RQ*
3
CNT
4
BT
5
LG(GND)
6
SD
7
SD*
8
9
SHD
P5 (+5V)
CMV1-R10P
8
4
5
7
6
9
10
1
2
3
A
B
C
D
U
V
W
A
B
C
D
CE05-2A18-10PD
MDS-D2-SP
LG
RQ*
SD*
2
4
6
8
10
P5(+5V)
RQ
SD
BT
1
3
5
7
9
U V W
CN2L
Power wire and grounding wire
(Refer to Specification manual for details
on selecting the wire.)
Optional cable: CNV2E
(Refer to Appendix 2 for details on the
cable treatment.)
Max : 30m
Encoder connector
NamePin
NamePinNamePin
Pin No.
Encoder connector : CN2L
No.9 No.1
No.10 No.2
Ground
NamePin
Power connector