Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 108
4 Setup
MITSUBISHI CNC
#3021
Not used. Set to "0".
#3022 sgear Encoder gear ratio
Set the deceleration rate of the encoder to the spindle when inputting ABZ pulse output encoder
feedback to NC during analog spindle control.
0: 1/1
1: 1/2
2: 1/4
3: 1/8
---Setting range---
0 to 3
#3023 smini Minimum rotation speed
Set the minimum spindle speed.
If an S command below this setting is issued, the spindle will rotate at the minimum speed set by this
parameter.
---Setting range---
0 to 32767 (r/min)
#3024(PR) sout Spindle connection
Select the connection method with a spindle drive unit.
0: No unit to connect
1: Optical digital communication (Mitsubishi spindle drive unit)
2 - 5: S-analog (Analog spindle drive unit)
---Setting range---
0 to 5
#3025 enc-on Spindle encoder
Set the connection specifications of a spindle's encoder.
0: Without encoder feedback when using analog spindle and connecting to NC
1: With encoder feedback when using analog spindle and connecting to NC
2: Mitsubishi spindle drive unit
---Setting range---
0 to 2
#3026 cs_ori Selection of winding in orientation mode
Select the coil control in orientation mode for the spindle motor which performs coil changeover.
0: Perform coil changeover based on the command from NC. (depending on the setting of
parameter #1239/bit0)
1: Use the coil L
#3027 cs_syn Selection of winding in spindle synchronization control mode
Select the coil control in spindle synchronization control mode for the spindle motor which performs
coil changeover.
0: Perform coil changeover based on the command from NC. (depending on the setting of
parameter #1239/bit0)
1: Use the coil H
#3028 sprcmm Tap cycle M command selection
Set the M codes for the spindle forward run/reverse run commands during tapping cycle.
High-order 3 digits: Set the M code for spindle forward run command.
Low-order 3 digits: Set the M code for spindle reverse run command.
When "0" is set, it is handled assuming that "3004" is set (the M code for spindle forward run
command is "3" and the M code for spindle reverse run command is "4").
---Setting range---
0 to 999999