Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 85
MDS-D2/DH2 Series Instruction Manual
4.3 Setting the Initial Parameters for the Spindle Drive Unit
SP182 IDSML Motor unique constants (L) 0000004453
SP183 R1L Motor unique constants (L) 000000104
SP184 00000090
SP185 TMLRL Motor unique constants (L) 000000120
SP186 TMLSL Motor unique constants (L) 000000150
SP187 KI1L Motor unique constants (L) 0000001078
SP188 PCNTL Motor unique constants (L) 0000000
: :::: ::
SP224 0000 00
SP225 SFNC5 Spindle function 5 0000 0000 0000 0000 0000 0000 0000
SP226 SFNC6 Spindle function 6 0000 0000 0000 0000 0000 0000 0000
SP227 SFNC7 Spindle function 7 0000 0000 0000 0000 0000 0000 0000
: :::: ::
SP232 0000 0000 0000 0000 0000 0000 0000
SP233 IVC Voltage non-sensitive band compensation 0000000
SP234 0000000
SP235 R2H Temperature compensation gain 0000000
SP236 WIH Temperature compensation time constant 0000000
SP237 TCF Torque command filter 500 500 500 500 500 500 500
SP238 SSCFEED Safely limited speed 0000000
SP239 SSCRPM Safely limited motor speed 0000000
SP240 0000000
:
SP256
Motor
Parameter
200V Standard motor SJ-V Series (Wide range constant output)
SJ-V11-
01T
SJ-V11-
09T
SJ-V15-
03T
SJ-V18.5-
03T
SJ-V22-
05T
SJ-V22-
09T
SJ-VK22-
19ZT
No. Abbrev. Details MDS-D2-SP- 160 160 200 240 320 320 320