5.5 Settings for Emergency Stop
[3] Servo drive unit controls power supply unit. Vertical axis is a 1-axis unit (vertical axis: Z axis).
(Note) For the standard setting value of SV056, refer to "Deceleration control".
[4] Servo drive unit controls power supply unit. Vertical axis is a 2-axis unit (vertical axis: Z axis).
(Note) For the standard setting value of SV056, refer to "Deceleration control".
Axis
Parameter
X axis Y axis Z axis (Vertical axis) Spindle
MDS-D2/DH2-V2 MDS-D2/DH2-V1 MDS-D2/DH2-SP
SV048 00
200ms as a standard
(Set by adjustment)
Set as follows.
SP055=20000
SP056=300
SV055 X, Y, Z axis Maximum value of SV056 setting value +100ms
SV056 Standard setting value for each axis (Note)
Axis
Parameter
X axis Y axis Z axis (Vertical axis) Spindle
MDS-D2/DH2-V1 MDS-D2/DH2-V2 MDS-D2/DH2-SP
SV048 0
Same value
as Z axis ->
200ms as a standard
(Set by adjustment)
Set as follows.
SP055=20000
SP056=300
SV055 X, Y, Z axis Maximum value of SV056 setting value +100ms
SV056 Standard setting value for each axis (Note)
MDS-D2/DH2-V1MDS-D2/DH2-V2 MDS-D2/DH2-SPMDS-D2/DH2-CV
NC
MDS-D2/DH2-CV
SpindlePower supply*Z axis Power supply
X axis, Y axis
MDS-D2/DH2-V2MDS-D2/DH2-V1 MDS-D2/DH2-SPMDS-D2/DH2-CV
NC
MDS-D2/DH2-CV
SpindlePower supplyY axis, *Z axis Power supply
X axis