Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 124
4 Setup
MITSUBISHI CNC
#13006 SP006 VIA1 Speed loop lead compensation 1
Set the speed loop integral control gain.
The standard setting is "1900". Adjust the value by increasing/decreasing the value by about 100.
Raise this value to improve the contour tracking accuracy in high-speed cutting.
Lower this value when the position droop does not stabilize (when the vibration of 10 to 20Hz
occurs).
---Setting range---
1 to 9999
#13007 SP007 VIL1 Speed loop delay compensation 1
Set this parameter when the limit cycle occurs in the full-closed loop or overshooting occurs in
positioning.
When setting this parameter, make sure to set the torque offset "SP050(TOF)".
When not using, set to "0".
---Setting range---
0 to 32767
#13008 SP008 VGN2 Speed loop gain 2
Normally SP005(VGN1) is used.
By setting "SP035/bit1, SP035/bit9 or SP036/bit1=1", gain 2 can be used according to the
application.
Gain 2 can also be used by setting "Speed gain set 2 changeover request (control input 5/ bitC) = 1".
Refer to SP005(VGN1) for adjustment procedures.
---Setting range---
1 to 9999
#13009 SP009 VIA2 Speed loop lead compensation 2
Normally SP006(VIA1) is used.
By setting "SP035/bit1, SP035/bit9 or SP036/bit1=1", gain 2 can be used according to the
application.
Gain 2 can also be used by setting "Speed gain set 2 changeover request (control input 5/ bitC) = 1".
Refer to SP006(VIA1) for adjustment procedures.
---Setting range---
1 to 9999
#13010 SP010 VIL2 Speed loop delay compensation 2
Normally SP007(VIL1) is used.
By setting "SP035/bit1, SP035/bit9 or SP036/bit1=1", gain 2 can be used according to the
application.
Gain 2 can also be used by setting "Speed gain set 2 changeover request (control input 5/ bitC) = 1".
Refer to SP007(VIL1) for adjustment procedures.
---Setting range---
0 to 32767
#13011 SP011
Not used. Set to "0".
#13012 SP012
Not used. Set to "0".
#13013 SP013
Not used. Set to "0".