9.1 Deceleration and Stop Function at Power Failure
(3) Parameter setting of servo drive unit
When using the deceleration and stop function at power failure, set the servo parameter of this function for the
servo drive unit connected to the power supply unit.
#2236(PR) SV036 PTYP Power supply type/ Regenerative resistor type
MDS-D2/DH2 Series: Power supply type
When connecting a power supply unit, set a code for each power supply unit.
bit F-C : amp
Set the power backup function to be used.
No function used : 0
Deceleration and stop function at power failure : 8
(4) Parameter setting of spindle drive unit
When using the deceleration and stop function at power failure, set the spindle parameter of this function for the
spindle drive unit connected to the power supply unit. To decelerate and stop the spindle at power failure, select the
spindle stop method by setting the parameter of the spindle to be decelerated to a stop.
#13032(PR) SP032 PTYP Power supply type/ Regenerative resistor type
MDS-D2/DH2 Series: Power supply type
When connecting a power supply unit, set a code for each power supply unit.
bit F-C : amp
Set the power backup function to be used.
No function used : 0
Deceleration and stop function at power failure : 8
#13230 SP230 SFNC10 Spindle function 10
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit B : pfdsr
Set the spindle stop operation at a power failure when the deceleration and stop function at power
failure is enabled.
Normal (Coast to a stop at power failure) : 0
Deceleration and stop at power failure : 8
ptyp
rtyp
amp
ptyp
rtyp
amp