Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 102
4 Setup
MITSUBISHI CNC
4.3.3 Spindle Specification Parameters
The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF and ON to enable
the parameter settings.
#3001 slimt 1 Limit rotation speed (Gear: 00)
Set the spindle rotation speed for maximum motor speed when gear 00 is selected.
Set the spindle rotation speed for the S analog output=10V during analog spindle control.
---Setting range---
0 to 99999 (r/min)
#3002 slimt 2 Limit rotation speed (Gear: 01)
Set the spindle rotation speed for maximum motor speed when gear 01 is selected.
Set the spindle rotation speed for the S analog output=10V during analog spindle control.
---Setting range---
0 to 99999 (r/min)
#3003 slimt 3 Limit rotation speed (Gear: 10)
Set the spindle rotation speed for maximum motor speed when gear 10 is selected.
Set the spindle rotation speed for the S analog output=10V during analog spindle control.
---Setting range---
0 to 99999 (r/min)
#3004 slimt 4 Limit rotation speed (Gear: 11)
Set the spindle rotation speed for maximum motor speed when gear 11 is selected.
Set the spindle rotation speed for the S analog output=10V during analog spindle control.
---Setting range---
0 to 99999 (r/min)
#3005 smax 1 Maximum rotation speed (Gear: 00)
Set the maximum spindle rotation speed which is actually commanded when gear 00 is selected.
Set this as smax1(#3005)<= slimit1(#3001).
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
#3006 smax 2 Maximum rotation speed (Gear: 01)
Set the maximum spindle rotation speed which is actually commanded when gear 01 is selected.
Set this as smax2(#3006)<= slimit2(#3002).
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
CAUTION
The configuration of the spindle specification parameters (#3001 to #3138) can differ depending on the NC.
This Instruction Manual explains using the configuration of the parameters for M700V/M70V Series.