4.2 Setting the Initial Parameters for the Servo Drive Unit
#2399-2437 SV199 - SV237
Not used. Set to "0".
#2438 SV238 SSCFEED Safely limited speed
Set the machine's safely limited speed for the SLS (Safely Limited Speed) function.
Set this parameter within the following setting ranges.
For linear axis: 2000mm/min or less
For rotary axis: 18000°/min (50r/min) or less
When not using, set to "0".
Related parameters: SV033/bitD, SV113/bitF, SV239
---Setting range---
0 to 18000 (mm/min) or (°/min)
However, when SV033/bitD=1, the setting range is from -32768 to 32767 (100 mm/min) or
(100°/min).
#2439 SV239 SSCRPM Safely limited motor speed
Set the motor's safely limited speed for the SLS (Safely Limited Speed) function.
Set a value to hold the following relationship.
Be aware when setting the parameter as the setting units for general motors and linear motors are
different.
<<For general motor>>
  SV239=(SV238/SV018) x (SV002/SV001)
  Only when the product is 0, set to "1".
<<For linear motor>>
  SV239=SV238/60
  Only when the product is 0, set to "1".
When not using, set to "0".
---Setting range---
For general motor:0 to 32767 (r/min)
For linear motor: 0 to 32767 (mm/s)
#2440-2443 SV240 - SV243
Not used. Set to "0".
#2444(PR) SV244 DUNIT Communication interpolation unit for communication among
drive units
Set the communication interpolation unit among drive units in high-speed synchronous tapping
control.
When set to "0", it will be regarded as 20 (0.05μm) is set.
Related parameters: SV129
---Setting range---
0 to 2000 (1/μm)
#2445-2456 SV245 - SV256
Not used. Set to "0".