Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
Appendix 5 - 10
Appendix 5 EMC Installation Guidelines
MITSUBISHI CNC
MX13 Series 3-phase high attenuation noise filter for 200V
Features
(a) Perfect for mounting inside control panel: New shape with uniform height and depth dimensions
(b) Easy mounting and maintenance work: Terminals are centrally located on the front
(c) Complaint with NC servo and AC servo noise: High attenuation of 40dB at 150KHz
(d) Safety Standards:UL1283, CSAC22.2 No.8, EN60939(SEMKO)
(e) Patent and design registration pending
Specifications
(Note) This is the value at Ta 50°C.
Refer to the following output derating for Ta > 50°C.
Contact: TDK-Lambda Corporation http://www.tdk-lambda.com/
Item
Type
MX13030 MX13050 MX13100 MX13150
1 Rated voltage (AC) 3-phase 250VAC (50/60Hz)
2 Rated current (AC) 30A 50A 100A 150A
3
Test voltage
(AC for one minute across terminal and case)
2500VAC (100mA) at 25°C, 70% RH
4
Insulation resistance
(500VDC across terminal and case)
100M min. at 25°C, 70% RH
5 Leakage current (250V, 60Hz) 3.5mA max 8mA max
6 DC resistance 30m max 11m max 5.5m max 3.5m max
7 Temperature rise 30°C max
8 Working ambient temperature -25°C to +85°C
9 Working ambient humidity 30% to 95% RH (non condensing)
10 Storage ambient temperature -40°C to +85°C
11 Storage ambient humidity 10% to 95% RH (non condensing)
12 Mass (typ) 2.8kg 3.9kg 11.5kg 16kg