Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
3 - 11
MDS-D2/DH2 Series Instruction Manual
3.2 Emergency Stop Observation
(3) Parameter setting for spindle drive unit
Starts the SLS (Safely Limited Speed) function.
#13229 SP229 SFNC9 Spindle function 9
bit F : ssc SLS (Safely Limited Speed) function
0: Disable 1: Enable
The digital signal input selection is set to "1" for the drive unit connected with the door state signal.
The digital signal input selection is set to "0" for the other drive unit not connected with the signal.
bit D : rps Safely limited speed setting unit
0: Normal 1: 100°/min
Change the setting units of the specified speed signal output speed (SP030) and safely limited
speed (SP238).
#13227 SP227 SFNC7 Spindle function 7
bit F-C : dis Digital signal input selection
0: No signal
1: SLS (Safely Limited Speed) function door state signal
4: Proximity switch signal detection
Other settings: setting prohibited
Sets the safely limited speed of the machine and motor for which the SLS (Safely Limited Speed) function is
executed.
#13238 SP238 SSCFEED Safely limited speed
Set the safely limited speed at the spindle end for the SLS (Safely Limited Speed) function.
When not using, set to "0".
---Setting range---
0 to 18000 (/min)
However, when SP229/bitD is set to "1", the setting range is from -32768 to 32767 (100/min).
#13239 SP239 SSCRPM Safely limited motor speed
Set the motor's safely limited speed for the SLS (Safely Limited Speed) function.
When not using, set to "0".
---Setting range---
0 to 32767 (r/min)
(Note) The value of the safely limited speed and safely limited motor speed must satisfy the following relation.
If this relation is not satisfied, the parameter error (37or E4) will occur. (Error parameter No. is 239.)
Checking this relation is executed when the drive unit is turned ON and parameter is changed and speed
observation mode (states when a speed observation command is turned ON) is entered.
Note that "1 (r/min)" is applied when the calculation result is "0 (r/min)"
SP238 :SSCFEED
360
X
= SP239 :SSCRPM
SP057 :GRA1
SP061 :GRB1