8 Maintenance
MITSUBISHI CNC
8.3.2 Replacing the Unit Fan
(1) Replacing parts
< MDS-D2 Series >
< MDS-DH2 Series>
Servo drive unit Spindle drive unit Power supply unit
Type
MDS-D2-
Fan type
Size
[mm]
Type
MDS-D2-
Fan type
Size
[mm]
Type
MDS-D2-
Fan type
Size
[mm]
V1-20
9WF0424H6D05 40SQ.
SP-20
9WF0424H6D05 40SQ.
CV-37 --
V1-40 SP-40 CV-75 under development
V1-80 SP-80 CV-110
9WF0624H4D04 60SQ.
V1-160 SP-160 9WF0624H4D04 60SQ. CV-185
V1-160W 9WF0624H4D04 60SQ. SP-200
MMF-09D24TS-MM6 90SQ.
CV-300
MMF-09D24TS-MM6 90SQ.
V1-320
MMF-09D24TS-MM6 90SQ.
SP-240 CV-370
V1-320W SP-320 MMF-12D24DS-MM6 120SQ. CV-450
MMF-12D24DS-MM6 120SQ.
V2-2020
9WF0424H6D05 40SQ.
SP-400 MMF-09D24TS-MMB 90SQ. CV-550
V2-4020 SP-640 MMF-12D24DS-MM6 120SQ.
V2-4040 SP2-2020
9WF0424H6D05 40SQ.
V2-8040 SP2-4020
V2-8080 SP2-4040S
V2-16080
9WF0624H4D04 60SQ.
SP2-4040
9WF0624H4D04 60SQ.
V2-160160 SP2-8040
V2-160160W MMF-09D24TS-MM6 90SQ. SP2-16080S
V3-202020
109P0424H3D13 40SQ.
SP2-8080
MMF-09D24TS-MM6 90SQ.
V3-404040 SP2-16080
Servo drive unit Spindle drive unit Power supply unit
Type
MDS-DH2-
Fan type
Size
[mm]
Type
MDS-DH2-
Fan type
Size
[mm]
Type
MDS-DH2-
Fan type
Size
[mm]
V1-10 --SP-20
9WF0424H6D05 40SQ.
CV-37
9WF0624H4D04 60SQ.
V1-20
9WF0424H6D05 40SQ.
SP-40 CV-75
V1-40 SP-80 9WF0624H4D04 60SQ. CV-110
V1-80 SP-100
MMF-09D24TS-MM6 90SQ.
CV-185
V1-80W 9WF0624H4D04 60SQ. SP-160 CV-300
MMF-09D24TS-MM6 90SQ.
V1-160
MMF-09D24TS-MM6 90SQ.
SP-200
MMF-09D24TS-MMB 90SQ.
CV-370
V1-160W SP-320 CV-450
V1-200 MMF-09D24TS-MMB 90SQ. SP-480 MMF-12D24DS-MM6 120SQ. CV-550
MMF-12D24DS-MM6 120SQ.
V2-1010 -- CV-750
V2-2010
9WF0424H6D05 40SQ.
V2-2020
V2-4020
V2-4040
V2-8040
9WF0624H4D04 60SQ.
V2-8080
V2-8080W MMF-09D24TS-MM6 90SQ.
POINT
When the drive unit of D2/DH2 Series which uses two cooling fans is in an emergency stop or alarm,
one of fans (upper one in the case of vertical layout, or either one in the case of horizontal layout) is stopped and power-
saving operation is performed. If the suspended fan is restarted by canceling the emergency stop, it is not a problem with
the fan.