4.3 Setting the Initial Parameters for the Spindle Drive Unit
#13024 SP024 INP In-position width
Set the in-position detection width.
Set the positioning accuracy required to the machine.
Lower setting value increases the positioning accuracy, but makes the cycle time (settling time)
longer.
The standard setting is "875".
---Setting range---
0 to 32767 (1°/1000)
#13025 SP025 INP2 2nd in-position width
Use this when detecting an in-position different from normal in-position width such as advancing the
in-position signal. The adjustment procedure is the same as SP024 (INP).
The standard setting is "875".
---Setting range---
0 to 32767 (1°/1000)
#13026(PR) SP026 TSP Maximum motor speed
Set the maximum motor speed.
If the motor speed exceeds the set maximum speed, an overspeed alarm will occur.
---Setting range---
1 to 32767 (r/min)
#13027 SP027 ZSP Motor zero speed
Set the motor speed for detecting zero speed.
If the motor speed drops below the set speed, the zero speed signal turns ON.
The standard setting is "50".
---Setting range---
1 to 1000 (r/min)
#13028 SP028 SDTS Speed detection set value
Set the motor speed for detecting the speed.
If the motor speed drops below the set speed, the speed detection signal turns ON.
The standard setting is 10% of the maximum motor speed.
---Setting range---
10 to 32767 (r/min)
#13029 SP029 SDTR Speed detection reset width
Set the hysteresis width in which the speed detection changes from ON to OFF.
If the setting value is small, the speed detection will chatter easily.
The standard setting is "30".
---Setting range---
10 to 1000 (r/min)
#13030 SP030 SDT2 2nd speed detection setting value
Set the specified speed of the specified speed output.
When carrying out digital output of the specified speed output, set SP229/bitC to "1".
It is not available for MDS-DJ-SP Series.
---Setting range---
0 to 32767 (r/min)
#13031(PR) SP031 MTYP Motor type
Set the control system of the spindle drive unit.
2200: Semi closed loop control
4200: Full closed loop control by using spindle side ABZ pulse output encoder
6200: Full closed loop control by using spindle side serial output encoder