5.2 Gain Adjustment
#2203 SV003 PGN1 Position loop gain 1
Set the position loop gain. The standard setting is "33".
The higher the setting value is, the more accurately the command can be followed, and the shorter
the settling time in positioning gets, however, note that a bigger shock will be applied to the machine
during acceleration/deceleration.
When using the SHG control, also set SV004 (PGN2) and SV057 (SHGC).
When using the OMR-FF control, set the servo rigidity against quadrant projection or cutting load,
etc. For the tracking ability to the command, set by SV106(PGM).
---Setting range---
1 to 200 (rad/s)
#2204 SV004 PGN2 Position loop gain 2
When performing the SHG control, set the value of "SV003 x 8/3" to "SV004".
When not using the SHG control, set to "0".
When using the OMR-FF control, set to "0".
Related parameters: SV003, SV057
---Setting range---
0 to 999 (rad/s)
#2257 SV057 SHGC SHG control gain
When performing the SHG control, set to SV003(PGN1)×6.
When not using the SHG control, set to "0".
When using the OMR-FF control, set to "0".
Related parameters: SV003, SV004
---Setting range---
0 to 1200 (rad/s)
#2237 SV037 JL Load inertia scale
Set the motor axis conversion total load inertia including motor itself in proportion to the motor
inertia.
SV037(JL)=(Jm+Jl)/Jm×100
Jm: Motor inertia
Jl: Motor axis conversion load inertia
For linear motor, set the gross mass of the moving sections in kg unit.
<<Drive monitor load inertia ratio display>>
Set SV035/bitF=1 and imbalance torque and friction torque to both SV032 and SV045, and then
repeat acceleration/deceleration for several times.
---Setting range---
For general motor: 0 to 5000 (%)
For linear motor 0 to 5000 (kg)