Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 126
4 Setup
MITSUBISHI CNC
#13017(PR) SP017 SPEC1 Spindle specification 1
Select the spindle specification.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-C : msr Motor series selection
0: 200V specification IM spindle motor
1: 200V specification IPM spindle motor
2: 400V specification IM spindle motor
3: 400V specification IPM spindle motor
4: 200V specification Tool spindle motor
bit B-5 :
Not used. Set to "0".
bit 4 : fdir Position feedback
Set the machine side encoder's installation polarity.
0: Forward polarity 1: Reverse polarity
bit 3 : vfb Speed feedback filter
0: Disable 1: Enable (2250Hz)
bit 2 : seqh READY ON sequence
0: Normal 1: High-speed
bit 1 : dfbx Dual feedback control
Control the position FB signal in full closed control by the combination of a motor side encoder and
machine side encoder.
0: Stop 1: Start
Related parameters: SP051, SP052
bit 0 : fdir2 Speed feedback polarity
Set the motor side encoder's installation polarity by a built-in motor.
0: Forward polarity 1: Reverse polarity
msr
fdir
vfb
seqh
fdir2
dfbx