Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 146
4 Setup
MITSUBISHI CNC
#13102 SP102 TMA2 OMR-FF movement averaging filter time constant 2
Set the movement averaging filter time constant in OMR-FF control.
The standard setting is "88".
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 711 (0.01ms)
#13103 SP103
Not used. Set to "0".
#13104 SP104 FFR0 OMR-FF inner rounding compensation gain for G0
Set the inner rounding compensation amount (drive side feed forward gain) in OMR-FF control.
When a shape tracking error is too large in OMR-FF control, adjust it by setting this parameter.
The higher the setting value is, the less the shape tracking error will be, however, overshooting
during acceleration/deceleration will increase.
Lower the value when vibration occurs during the G0 acceleration/deceleration.
The standard setting is "10000".
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 20000 (0.01%)
#13105 SP105 FFR1 OMR-FF inner rounding compensation gain for G1
Set the inner rounding compensation amount (drive side feed forward gain) in OMR-FF control.
When a shape tracking error is too large in OMR-FF control, adjust it by setting this parameter.
The higher the setting value is, the less the shape tracking error will be, however, overshooting
during acceleration/deceleration will increase.
Lower the value when vibration occurs during the G1 acceleration/deceleration.
The standard setting is "10000".
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 20000 (0.01%)
#13106 SP106 PGM OMR-FF scale model gain
Set the scale model gain (position response) in OMR-FF control.
Set the same value as SV002(PGN).
Increase the setting value to perform a high-speed machining such as a fine arc or to improve the
path error.
Lower the value when vibration occurs during acceleration/deceleration.
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 300 (rad/s)
#13107-13111 SP107-SP111
Not used. Set to "0".
#13112 SP112 IFF OMR-FF current feed forward gain
Set the current feed forward rate in OMR-FF control.
The standard setting is "10000".
Setting value of 0 is equal to "10000(100%)" setting.
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 32767 (0.01%)