4.3 Setting the Initial Parameters for the Spindle Drive Unit
#3017 stapt 1 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 00)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 00 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
#3018 stapt 2 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 01)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 01 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
#3019 stapt 3 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 10 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)
#3020 stapt 4 Synchronous tapping 1st step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when
gear 11 is selected. (linear acceleration/deceleration pattern)
---Setting range---
1 to 5000 (ms)